Skip to main content
Version: ROS 2 Humble

User Bay Cover

Sales Kits

note

These kits require a Husky with a Top Plate. Refer to the Top Plate page for further details.

DescriptionSales KitInstallation Kit, With Fasteners
Installation, Kit, Cover, User Bay—Husky, Blank026947027228
Installation, Kit, Cover, User Bay—Husky, Connectors027255027254
Installation, Kit, Cover, User Bay—Husky, Fans and Connectors027194027250

Parts List

IDDescriptionCPR itemQuantity
1APlate—Connector Bulkhead, Blank0268551
1BPlate—Connector Bulkhead, Connector Cutouts0272561
1CPlate—Connector Bulkhead, Fan and Connector Cutouts0271951
2Gasket—Connector Bulkhead, Rubber0294271
3Screw, Cap, Round Head—M5×0.8 X 8, Stainless Steel02331618
4Washer—Ø5.3 X Ø10 X 2.36, Rubber02927818
5(Optional) Fan Guard—60 mm0111552

Tools

  • Hex Key, 3 mm
  • Torque wrench (optional, for safety applications)
  • Loctite 243 (optional, for high vibration applications)

Installation

Step 1

Place the Gasket (ID2) on the Husky's Top Plate.

Step 2

Place the Connector Plate (ID1) on the Gasket.

Step 3

Use 18 screws (ID3) and washers (ID4) to fasten the Connector Plate to the Husky. Torque these screws to 5 N·m.

note

You may add a small amount of thread locker to these screws if you are concerned about them loosening from high vibration applications.